- Home
- Skills
- Research & Analysis
- NVH FRF & Modal Analysis
Works with the AI Agents you already use
NVH FRF & Modal Analysis
Turn FRF exports from NVH tests or CAE (Nastran, Abaqus, Simcenter) into natural frequencies, half-power damping, Q factors, target-line exceedances and test-vs-simulation correlation (FRAC), with plots and a report.
Free
NVH FRF & Modal Analysis
Example session with this skill installed
Analyse test.csv (receptance, real/imag) between 10 and 480 Hz. Give me the natural frequencies and damping, check it against target.csv, and correlate it with my Nastran SOL111 result sim.csv.
- Read your context and instructions
- Compiled the nvh frf
- Generated the data export
Summary
Found 3 well-separated modes between 10 and 480 Hz. Two bands exceed the target line, and the simulation is 3-7 % off in frequency with a low FRAC (0.21), so the CAE model needs updating before it can be used for target-setting.
- Band: 10.0–480.0 Hz, resolution 0.250 Hz, 3 peaks (prominence ≥ 3.0 dB)
Modes
| mode | freq_hz | peak_mag | peak_db | prominence_db | damping_ratio_pct | q_factor | coupled_flag |
|---|---|---|---|---|---|---|---|
| 1 | 42 | 3.59025 | 11.1 | 26.33 | 2.012 | 24.8 | False |
| 2 | 118 | 0.607075 | -4.34 | 45.78 | 1.5 | 33.3 | False |
| 3 | 311 | 0.0445697 | -27.02 | 20.6 | 3.017 | 16.6 | False |
Target exceedances
| f_start_hz | f_end_hz | max_exceedance_db |
|---|---|---|
| 10 | 61 | 31.1 |
| 109 | 129.5 | 15.66 |
Correlation
- FRAC over band: 0.205
| mode | f_ref_hz | f_cmp_hz | dev_pct |
|---|---|---|---|
| 1 | 42 | 45 | 7.14 |
| 2 | 118 | 112 | -5.08 |
| 3 | 311 | 321 | 3.22 |
Findings
Mode 1 (42 Hz, 2.0 % damping) drives the largest exceedance (+31 dB over the target from 10-61 Hz). This is the primary target for a stiffness or damping countermeasure.
Mode 2 (118 Hz, 1.5 %) is the most lightly damped mode (Q = 33) and exceeds the target by 15.7 dB between 109 and 130 Hz.
- No coupled modes were flagged, so the half-power damping estimates are reliable at 0.25 Hz resolution.
Correlation: simulation over-predicts mode 1 (+7.1 %) and mode 3 (+3.2 %) and under-predicts mode 2 (-5.1 %). Mixed signs point to a local stiffness or mass distribution error rather than a global material property.
Next steps
- Review joint/connection stiffness in the CAE model near the components that dominate mode 1 and mode 2.
- Run a sensitivity study, then model-update until frequency deviation is below 3 % and FRAC exceeds 0.8.
- Evaluate a damping treatment targeting 100-130 Hz for mode 2.
Files written: results/modes.csv, results/frf_plot.png, results/report.md.
modes.csv
CSV · data export
Example file from a real run - the skill writes it into your workspace.
Connects securely to your tools. The creator never sees your data.
About this skill
What it does
Give your agent a frequency response function (FRF) file and get an engineering-grade modal summary back:
- Resonance detection: peak picking with a configurable prominence threshold
- Modal damping: half-power (-3 dB) bandwidth damping ratio and Q factor per mode
- Target-line checks: frequency bands where the FRF exceeds your limit, with maximum exceedance in dB
- Test vs. CAE correlation: matched-mode frequency deviation (%) and FRAC over the band
- Outputs: modes.csv, magnitude/phase plot (PNG) and a Markdown report
Who it is for
NVH, CAE and test engineers in automotive, aerospace and machinery who post-process FRFs from shaker or impact-hammer tests, or from Nastran SOL111 / Abaqus steady-state dynamics runs.
Built-in engineering checks
It flags closely spaced (coupled) modes where half-power damping is biased, damping values that point to noise or leakage, and frequency resolution too coarse for reliable damping, then recommends next steps (curve-fitting, damping treatment, model updating).
Input formats
CSV, TXT or Excel with frequency plus real/imag, magnitude/phase, or dB/phase columns. Format is auto-detected.
Limitations
SISO FRFs only (no mode shapes). Half-power damping is an estimate; for heavily damped or closely spaced modes use a dedicated curve-fitter such as PolyMAX/LSCF.
Supports SISO FRFs only. Half-power damping is unreliable for coupled modes or resolution coarser than 1 Hz below 200 Hz. No geometry/mode shape visualization.
How to use
- 1
Connect your agent to the Agensi MCP
Copy the prompt and paste it into Claude, ChatGPT, Cursor or any agent that supports MCP. It sets up the connection for you. Manual setup
- 2
Sign in to Agensi
Your agent shows a sign-in link. Sign in and click Allow.
- 3
Ask for what you need
Your agent loads this skill and uses it on your task. It always asks before any payment.
Reviews
No reviews yet
Be one of the first to try it. Every listed skill goes through the trust checks below.
Security scanned
Checked by our 8-point scan before listing
Fresh listing
Recently published to Agensi
Free forever
No account required to browse
Trust & safety
Security scan
Security scan passed 20 days ago
- Free with an Agensi account
Requires
Permissions
Runs a local Python script that reads the FRF files you point it to and writes results (CSV, PNG, Markdown) to an output folder. No network access.