- Home
- Skills
- Workflow Automation
- Datumsmith: CAD That Proves Its Parts (CadQuery, DFM, ISO)
More screenshots
Works with the AI Agents you already use
Datumsmith: CAD That Proves Its Parts (CadQuery, DFM, ISO)
Datumsmith gives your agent a design workflow with sourced numbers and deterministic checks on the real geometry.
$19
Datumsmith: CAD That Proves Its Parts (CadQuery, DFM, ISO)
Example session with this skill installed
Check sensor_cover.step for FDM printing, including the screw holes. Then tell me whether housing.step can be injection moulded and which pull direction is best.
- Read your context and instructions
- Compiled the datumsmith
Summary
Two checks on the buyer's own STEP files. The FDM check fails on a 0.6 mm wall and flags two screw holes that are near, but not at, a standard size. The moulding check passes walls and draft, finds one undercut and picks +Z as the best pull direction.
sensor_cover.step: FDM, with fastener holes
$ check_dfm.py sensor_cover.step --process fdm --fasteners
check_dfm: FAIL
[ fail] min_wall: min 0.6 mm, p1 0.6 mm, 621 sample(s) below 0.8 mm (fails at >= 3)
fix: Thicken walls at the listed locations to >= 0.8 mm.
[ pass] overhang: 0 mm^2 steeper than 45.0 deg from vertical (up +Z, bed faces excluded)
[ warn] fastener_fit: 2 round hole(s): 0 match, 2 near-miss
fix: Snap near-miss holes to the listed standard diameter (or document the intentional fit).
housing.step: injection moulding, pull direction search
$ check_dfm.py housing.step --process injection_molding --up +Z --orient-search
check_dfm: WARN
[ pass] min_wall: min 1.6763 mm, p1 1.6926 mm, 0 sample(s) below 1.14 mm (fails at >= 3)
[ pass] draft: 0 face(s) drafted less than 0.5 deg to the pull +Z (0 mm^2)
[ warn] undercut: 1 face(s) not reachable from either mould half along +Z
fix: Remove the undercut (through-cut shut-off, reorient the feature to the pull) or plan a
side action/lifter, which adds tooling cost.
metrics.molding: projected_area_mm2 1200.0, undercut_by_pull_axis {Z: 44.7, Y: 2967.0, X: 2936.7}, best Z
| Part | Process | Status | What to fix |
|---|---|---|---|
| sensor_cover.step | FDM | FAIL | 0.6 mm walls; 2 holes off the standard size |
| housing.step | Injection moulding | WARN | 1 undercut face along +Z |
Next steps
- Thicken the reported walls to at least 0.8 mm in the CadQuery source and re-run the same check.
- Snap the two holes to the listed ISO 273 or heat-set insert diameter, or record the intentional fit in the contract.
- Remove the undercut with a shut-off or by turning the feature to +Z, or plan a side action and its tooling cost.
Connects securely to your tools. The creator never sees your data.
About this skill
An agent that writes a CAD script is not the same as an agent that delivers a part you can print, machine or mould. Datumsmith gives your agent a design workflow with sourced numbers and deterministic checks on the real geometry.
What it does
- Design rules with sources. FDM, SLA, SLS, MJF, metal printing, CNC, injection moulding and sheet metal values, each tagged verified, disputed or unverified. Only verified rules fail a part; the rest warn.
- DFM on the BRep. Minimum wall, overhang (teardrop holes recognised), bridges, holes against ISO 273 / tap-drill / heat-set insert tables, enclosed voids; for moulding also draft per face, undercuts along the pull, projected area and the best pull axis.
- Design contracts. A JSON list of holes, bosses, cut-outs and keep-outs is checked feature by feature on the STEP, and failures name the feature id.
- Fit checks. Interference volume and minimum gap between parts (lid vs PCB, insert vs boss).
- ISO 286. Tolerance limits for IT5–IT11, shafts c–s and holes H, G, F, JS, K, M, N, P up to 500 mm.
- Technical drawings. ISO first-angle sheet with title block, datum dimensions, wall and fit callouts, in English or Turkish.
How it works
Request → inspect existing CAD → write a contract and pick sourced rules → build a parametric CadQuery script → validate (features, STEP round trip, fit, DFM, mesh) → only then export STEP, STL and the drawing. Every checker prints a JSON report with expected value, actual value and a fix hint, and the agent re-runs it after each fix.
What you get
The workflow (SKILL.md), 25 reference files with the sourced rule tables per process, and 18 self-contained scripts: feature, STEP, fit, DFM and mesh checkers, renders and measured sections, the drawing generator, an ISO 286 calculator and an optional two-part enclosure generator.
Where it stops
It reduces mistakes; it does not certify parts. Loads, fatigue, creep and safety factors need an engineer. Your supplier's specification wins over any rule value. Print or machine a test piece before production.
Needs local Python 3.11+ with CadQuery 2.8 (and build123d for drawings); browser-only chat cannot run the scripts. Millimetres only. Checks geometry against sourced manufacturing rules but does no structural, fatigue or thermal analysis. Rules marked disputed or unverified only warn, so print or machine a test piece. It cannot read images or PDFs of drawings: give dimensions as text or a STEP file.
How to use
- 1
Connect your agent to the Agensi MCP
Copy the prompt and paste it into Claude, ChatGPT, Cursor or any agent that supports MCP. It sets up the connection for you. Manual setup
- 2
Sign in to Agensi
Your agent shows a sign-in link. Sign in and click Allow.
- 3
Ask for what you need
Your agent loads this skill and uses it on your task. It always asks before any payment.
Reviews
No reviews yet
Be one of the first to try it. Every listed skill goes through the trust checks below.
Security scanned
Checked by our 8-point scan before listing
Fresh listing
Recently published to Agensi
Money-back guarantee
Doesn't do what its page promises? You get your money back.
Trust & safety
Security scan
Security scan passed 16 days ago
Requires
Permissions
Runs the bundled checker scripts locally in the terminal, reads the user's STEP/STL and JSON files, and writes CAD, mesh, report and drawing files into the project. Reads CADQUERY_PYTHON / BUILD123D_PYTHON only to locate the interpreters. No network access.