CT

    Can This French Dwelling Be Let? Decency & DPE

    1

    Decency, energy performance, the DPE letting calendar, mandatory diagnostics and their expiry, authorisation zones - each with its text.

    $39

    Secure checkout via Stripe

    Money-back guarantee

    Converts to your local currency at checkout

    Security scanned

    Works with the AI Agents you already use

    Claude CodeClaude CodeCursorCursorCodex CLICodex CLIMuseMuseDotsDots+21 more
    CT

    Can This French Dwelling Be Let? Decency & DPE

    Example session with this skill installed

    Run a compliance check on lot_42.json for the date 2026-01-01. The dwelling is 18m3, 8m2, DPE class G from 2022, and located in a prior-authorisation zone.

    • Read your context and instructions
    • Compiled the can this french

    I have processed the compliance check for the specified dwelling against the French decency and energy performance criteria for January 1, 2026. The analysis identified multiple blocking factors that prevent this property from being lawfully let on that date.

    Dwelling Compliance Audit: Lot 42

    FindingSeverityLegal ReferenceVerdict
    Geometric DecencyCRITICALDecree n°2002-120 Art. 2NON-COMPLIANT: Volume (18m³) is below the 20m³ threshold, and area (8m²) is below 9m².
    Energy PerformanceCRITICALLaw Resilience 2021 / CCHNON-COMPLIANT: Class G dwellings are prohibited from new leases or renewals starting Jan 1, 2025.
    Prior AuthorisationBLOCKINGALUR Law / CCH L. 635-1MISSING: Location in a designated zone requires "Permis de louer" before lease signature.
    DPE ValidityVALIDDecree 2020-1610OK: DPE established in 2022 remains valid until 2032 (though class blocks letting).
    ERP (Risks)EXPIREDEnvironment Code L. 125-5EXPIRED: State of risks and pollution reports must be less than 6 months old.

    Summary Verdict: This dwelling cannot be let. It fails the fundamental decency threshold for volume and area, and is subject to the 2025 energy performance ban for Class G properties.

    Next steps

    • Immediate Action: Commission a new ERP (State of Risks) report as the current one is expired.

    Structural Review: Assess if the room volume can be increased or merged with another lot; otherwise, it cannot be used as a main residence.

    Renovation Planning: Consult EXPERT.md for works required to move the DPE from G to at least E to meet post-2025 decency standards.

    Connects securely to your tools. The creator never sees your data.

    About this skill

    Not "is it compliant" — can this one be let, on this date, and what blocks it.

    Decide whether a French dwelling can lawfully be let, and what is missing - decency criteria, energy performance and the DPE letting calendar, the mandatory diagnostics and their validity dates, prior-authorisation zones, tenant insurance - each finding with the text it rests on. Use when a property manager prepares a letting, audits a portfolio, buys a building, or must answer a tenant or an inspection about a dwelling's condition.

    Tested scripts: scripts/controler_lot.py returns every finding with its reference and a verdict. On a 7.5 m² dwelling under a 2.1 m ceiling, class G, DPE from 2012, in a prior-authorisation zone, it returns ten findings - decency, energy decency, the class G ban, an expired DPE, four missing diagnostics, no authorisation, no insurance certificate - and says it cannot be let. On a compliant 32 m² flat from 1972 it returns nothing and says so. Pass --date to answer "and in two years?", which is the question an owner actually asks before deciding between works and a sale.

    Which diagnostics are required is derived from the dwelling rather than from a universal list: construction year brings lead and asbestos into scope, installations over fifteen years bring electricity and gas. Then each date is checked - an expired DPE blocks exactly like a missing one, and the state-of-risks report is the one that expires fastest at six months.

    Two mechanisms are commonly confused and the skill separates them: the energy decency threshold works on the consumption figure and bites first, while the class calendar removes classes from the rental market one after another. A dwelling can be class F and already indecent on consumption.

    Includes an EXPERT.md reference (exact parameters, thresholds, failure diagnosis): the texts, the geometric floor, the two energy mechanisms, which works actually move a class and the two traps that come with them - internal insulation reduces habitable surface and can push a marginal dwelling below the floor, and insulating without ventilating creates damp, which is itself an indecency - the diagnostics matrix with validity, a remediation priority order that stops owners agonising over insulation while a 150-euro report blocks the lease, portfolio scanning, and what a scan cannot see.

    It says plainly what it does not do: it tests structured data, not condition. Damp, an unsafe staircase, a window that will not close, pests - all decency matters, all requiring a visit. "Nothing found" means nothing found on the points checked, and that sentence belongs in the report.

    Acceptable use: assessing dwellings you own, manage or are mandated to audit. The skill refuses omitting a blocking finding from a report, backdating a diagnostic, advising how to let a dwelling that cannot lawfully be let, and using the output to select tenants rather than to assess dwellings.

    Not legal advice. The decency criteria, the energy thresholds and the calendar have been amended and debated more than once, and local rules add to them: confirm the current texts before acting on an edge case.

    Cannot detect physical damage (damp, broken stairs) not in data. Requires manual verification of current local urbanism rules. Use limited to property assessment, not tenant selection.

    How to use

    1. 1

      Connect your agent to the Agensi MCP

      Copy the prompt and paste it into Claude, ChatGPT, Cursor or any agent that supports MCP. It sets up the connection for you. Manual setup

    2. 2

      Sign in to Agensi

      Your agent shows a sign-in link. Sign in and click Allow.

    3. 3

      Ask for what you need

      Your agent loads this skill and uses it on your task. It always asks before any payment.

    Reviews

    No reviews yet

    Be one of the first to try it. Every listed skill goes through the trust checks below.

    Security scanned

    Checked by our 8-point scan before listing

    Fresh listing

    Recently published to Agensi

    Money-back guarantee

    Doesn't do what its page promises? You get your money back.

    Trust & safety

    Security scan

    Security scan passed 27 days ago

    Requires

    Python

    Permissions

    Terminal / Shell
    Read Files
    Write Files
    Listed27 days ago

    What's inside

    Frequently Asked Questions

    The skill requires a structured JSON file containing the property's characteristics (area, ceiling height, DPE class, and diagnostic dates). It uses a Python-based logic engine to compare these values against French housing decrees.

    Unlike general AI, this skill uses hardcoded legal logic to prevent 'hallucinations' regarding French energy calendars. It mathematically calculates volume thresholds and cross-references specific articles of the French Construction and Housing Code.

    The skill is built in standard Python 3 with no external dependencies, making it compatible with any AI agent or workflow engine that can execute Python scripts and process JSON outputs.

    Yes, by using the `--date` flag, the skill can simulate future compliance states. It will tell you exactly when a property with a specific DPE rating (like F or G) will officially become unlettable under the French energy calendar.

    The purchase includes the Python source code for the auditing engine and the structured logic for French housing decency. It is designed for offline use and does not require an API key or a network connection to function.

    This skill audits compliance based on provided data, such as diagnostic expiry and dimensions. It cannot 'see' physical conditions like mold, electrical safety hazards, or structural leaks unless those factors are explicitly noted in your input data.